          Gold-life micropump development and production center

          Homepage
          Favorite

          | Center introduction| Product Introduction | Applied Communication |  Services  | Contact|

          Select micro-pump

          pressure unit conversion table

          GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb

          Name and model

          Voltage

          (V)

          No-load Current

          (mA)

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          (mL/min)

          Weight

          (g)

          Pump Size

          Detailed Structure of the show

          reference Appearance

          GminiPA-1

          3.5

          30-50

          35

          -25

          800

          16

          162431

          >>here

          GminiPA-2

          3.5

          30-40

          35

          -20

          300

          16

          162431

          >>here

          Ibid

          pressure unit conversion table

          GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb.

          Name and model

          Voltage

          (V)

          No-load Current

          (mA)

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          (mL/min)

          Weight

          (g)

          Pump Size

          Installation instructions

          Detailed Structure of the show

          reference Appearance

          GminiPB-1

          3.5

          100

          35

          -25

          800

          28

          162441

          >>here

          GminiPB-2

          3.5

          100

          35

          -20

          300

          28

          162441

          >>here

          Ibid

          GMPA Series of micro-Pump  the pump size is small, current, power consumption, low noise, stable and reliable, with mounting holes for the lithium battery-powered instrument for the pursuit of high-quality user ,With special needs can be put on a positive pressure above 0.1mpa Suction pump for pocket analyzer, gas sampler, medical instrument, beauty instrument and so on.

          Name and model

          Voltage

          (V)

          No-load Current

          (mA)

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          (L/min)

          Weight

          (g)

          Pump Size

          Installation instructions

          Structure of the show

          reference Figure

          GMPA-1

          1.5-5

          test:4V

          40-100

          50

          20-30

          0.3-1.5

          35

          402336

          flow-load diagram

          voltage-flow chart

          Structure>>here

          GMPA-2

          2.0-5

          test:4V

          30-100

          50

          30-40

          0.5-2.0

          35

          402336

          Ibid

          Ibid

          GMPA-3

          3-6

          40-70

          50

          20-30

          0.5-1.5

          35

          402336

          Ibid

          Ibid

          GMPA-4

          3-6

          50-90

          50

          30-40

          0.5-1.8

          35

          402336

          Ibid

          Ibid

          GMPC Series of micro-pump   the pump size is small, low noise, small power consumption,stable and reliable hand-held devices used to pump suction. particularly suitable for demanding vacuum environments. with special needs can be put on a positive pressure above 0.1mpa .suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

          Name and model

          Voltage

          (V)

          No-load Current

          (mA)

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          (L/min)

          Weight

          (g)

          Pump Size

          Installation instructions

          Structure of the show

          reference Figure

          GMPC-1/2/3

          6/9/12

          <200/120/90

          >100

          50-65

          2.5-3

          45

          502231

          Structure>>here

          flow-load diagram

          voltage-flow chart

          GMPC-4/5/6

          6/9/12

          <150/110/80

          >80

          50-55

          2.0-2.5

          45

          502231 ibid

          ibid

          GMPD Series of micro-pumpsuction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump with special needs can be put on a positive pressure above 0.1mpa .

          Name and model

          Voltage

          (V)

          No-load Current

          (mA)

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          (L/min)

          Weight

          (g)

          Pump Size

          Installation instructions

          Structure of the show

          reference Figure

          GMPD-1/2/3

          6/12/24

          <230/130/80

          60-100

          60

          3-8

          82

          3544.556.5

          flow-load diagram

          voltage-flow chart

          Structure>>here

          GMPD-4/5/6

          6/12/24

          <200/100/60

          60-100

          50

          3-7

          82

          3544.556.5 ibid

          ibid

          Custom products 6,9,12,24 volts, flow 2L, 3l, 4l can be customized, there are 20 models

          GMPE Series of micro-pump To provide a special and long life motor, flow rate no less, suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

          Name and model

          Voltage

          (V)

          No-load Current

          mA

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          L/min

          Weight(g)

          Pump Size

          Structure of the show

          reference Figure

          GMPE-1/2

          12/24

          <180/90

          60

          50-55

          3-6

          149

          33543.572

          flow-load diagram

          voltage-flow chart

          Structure>>here

          GMPE-3/4/-

          12/24 -20-40 Custom 3L4L5L 149 3543.572

          Note: The custom products 2L, 3L, 4L can be customized, a total of 10 variety

          GMPF Series of micro-pump   A single-channel pump, flow is very stable, suitable for a variety of gas sampling.

          Name and model

          Voltage

          (V)

          No-load Current

          A

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          L/min

          Weight(g)

          Pump Size

          Structure of the show

          reference Figure

          GMPF25-1/2

          12/24 0.6/.3 >100 -70 25 480 8656.5126

          Structure>>here

          GMPF15-3/4

          12/24 0.6/0.3 >60 -50 18 480 8656.5126

          Structure>>here

          GMPG Series of micro-pump A new single-channel pump, flow is very stable, suitable for a variety of gas sampling, changes in motor and voltage can produce six varieties.

          Name and model

          Voltage

          (V)

          No-load Current

          A

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          L/min

          Weight(g)

          Pump Size

          Structure of the show

          reference Figure

          GMPG-1/2

          6-12/24

          <0.450

          100

          20-50

          36

          620

          8670126

          Structure>>here

          GMPG-3/4

          6-9/24

          <0.550

          100

          20-50

          36

          620

          8670126

          ibid

          GDMPB Series Mini Double Pump        The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

          Name and model

          Voltage

          (V)

          No-load Current

          A

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          L/min

          Weight(g)

          Pump Size

          Structure of the show

          reference Figure

          GDMPB-1/2

          6/12

          <0.25/0.135

          100

          series260

          -45-55

          series vacum

           -85

          single:22

          dual:2.8

          55

          244749

          flow-load diagram

          voltage-flow chart

          Structure>>here

          GDMPB-3/4

          6/12

          <0.25/0.135

          100

          series260

          50-65

          single:2.52

          dual:3.8

          55

          244749

          ibid

          GDMPC Series Mini Double Pump   The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

          Name and model

          Voltage

          (V)

          No-load Current

          A

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          L/min

          Weight(g)

          Pump Size

          Structure of the show

          reference Figure

          GDMPC-1/2

          12/24

          <0.135/0.08

          100

          series260

          -45-55

          series vacum

          -75

          single

          22L/min

          dual

          2.8L/min

          75

          244751

          flow-load diagram

          voltage-flow chart

          Structure>>here

          GDMPC-3/4

          12/24

          <0.135/0.08

          series

          260

          -50-65

          series vacum

          -80

          single:2.52

          dual:3.8

          5

          244751

          ibid

          GDMPD Series Mini Double Pump  The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit cost, function more flexible.

          Name and model

          Voltage

          (V)

          No-load Current

          mA

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          L/min

          Weight(g)

          Pump Size

          Structure of the show

          reference Figure

          GDMPD-1/2

          12/24

          <200

          /135

          100

          -40-50

          series vacum

          -75

          single:72

          dual:10

          107

          354855.5

          GDMPD-3/4

          12/24

          <240

          /135

          100

          -40-60

          series vacum

          -80

          single:82

          dual:11

          107

          354855.5

          GDMPD-5/6

          12/24

          <180

          /115

          100

          -35-45

          single:52

          dual:8

          107

          354855.5

          GDMPE Series Mini Double Pump The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit costs, function more flexible and longer motor life

          Name and model

          Voltage

          (V)

          No-load Current

          mA

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          L/min

          Weight(g)

          Pump Size

          Structure of the show

          reference Figure

          GDMPE-1/2

          12/24

          <180/100

          100

          -40-50

          series vacum

          -75

          single:62

          dual:10

          175

          354871.5

          flow-load diagram

          voltage-flow chart

          Structure>>here

          GDMPF Series Mini Double Pump  Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, micro-organisms, a variety of gas sampling. gas line more stable.

          Name and model

          Voltage

          (V)

          No-load Current

          A

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          L/min

          Weight(g)

          Pump Size

          Structure of the show

          reference Figure

          GDMPF(40)-1/2

          12/24

          0.80

          100

          20-60

          single:282

          dual:40

          618

          1056.5126

          voltage-flow chart

          Structure>>here

          GDMPF(25)-3/4

          12/24

          0.70

          100

          20-60

          single:202,

          dual:25

          663

          1056.5126

          ibid

          GDMPG Series Mini Double Pumpuse of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, sampling of the double-headed just need a pump

          Name and model

          Voltage

          (V)

          No-load Current

          A

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          L/min

          Weight(g)

          Pump Size

          Structure of the show

          reference Figure

          GDMPG(50)-1/2

          6-12/24

          <1.0

          60

          20-50

          single:352

          dual:50

          759

          11070126

          Structure>>here

          GDMPG(35)-3/4

          6-12/24

          <1.0

          -50-60

          20-50

          single:252

          dual:50

          759

          11070126

          Structure>>here

          GFMPE Series of four-channel Pump Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, can be composed of a four-way mixed-constant pump, flow is very stable.

          Name and model

          Voltage

          (V)

          No-load Current

          A

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          L/min

          Weight(g)

          Pump Size

          Structure of the show

          reference Figure

          GFMPE-1/2 12/24 <0.67/0.35 -- 60 Four:5-18 375 4564.5124

          Structure>>here

          GFMPE-3/4

          12/24

          <0.67/0.35.67

          --

          45

          Four:3-15

          375 4564.5124
          Other Four:1-10 375 4564.5124

          HLA-2 Manual vacuum sampler series Test tube-specific, non-electric manual, negative pressure changes with the personal power

          Name and model

          Voltage

          (V)

          No-load Current

          mA

          Pressure

          (kPa)

          Vacum

          (kPa)

          Intake Flow

          L/min

          Weight(g)

          Pump Size

          Structure of the show

          reference Figure

          HLA-2

          --

          50mL and 100mL two tranches.

          Help